Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 537
Filter
1.
Philippine Journal of Ophthalmology ; : 67-73, 2023.
Article in English | WPRIM | ID: wpr-1003658

ABSTRACT

Objective@#This study evaluated the functional and cosmetic outcomes after bilateral frontalis sling repair using either expanded polytetrafluoroethylene (ePTFE) or silicone rod for unilateral or bilateral severe congenital ptosis with poor levator function.@*Methods@#This was a non-comparative, interventional case series involving 30 patients with unilateral or bilateral severe congenital ptosis who underwent bilateral frontalis sling repair from February 2012 to November 2018. Medical records including pre- and postoperative photographs were reviewed. The functional and cosmetic outcomes were assessed.@*Results@#There were 15 patients with severe congenital ptosis who underwent ePTFE surgery and 15 patients who had silicone rod surgery. Baseline levator function measured was less than 5 mm in all patients. The mean follow-up duration after surgery was 15.6+6.9 months. Satisfactory eyelid contour was observed in all patients (100%). Postoperatively, all had good to excellent primary eyelid position and effective frontalis action on eyelid elevation. Complications included exposure of the silicone sling material after trauma at the brow area (n=1) and recurrence of ptosis (n=2).@*Conclusion@#Bilateral frontalis suspension in patients with severe congenital ptosis, whether bilateral or unilateral, resulted in excellent functional and cosmetic outcomes using ePTFE or silicone rod.


Subject(s)
Polytetrafluoroethylene
2.
Journal of Central South University(Medical Sciences) ; (12): 94-100, 2022.
Article in English | WPRIM | ID: wpr-929010

ABSTRACT

OBJECTIVES@#Due to the lack of large-sized pulmonary valved conduit products in clinical practice, hand-sewn expanded polytetrafluoroethylene (ePTFE) valved conduit has been used for right ventricular outflow tract (RVOT) reconstruction in many heart centers around the world. This study aims to summarize the early results of the ePTFE valved conduit and the sewing technology of the conduit in combination with the latest progress, and to provide a reference for the application of ePTFE valved conduit.@*METHODS@#A total of 21 patients using ePTFE valved conduit for RVOT reconstruction in the Second Xiangya Hospital, Central South University from October 2018 to October 2020 were prospectively enrolled in this study. The age at the implantation of the conduit was 4.3 to 43.8 (median 15.1) years old, with weight of (38.9±4.1) kg. In this cohort, 14 patients underwent re-reconstruction of RVOT, including 12 patients with pulmonary regurgitation at 6.3 to 31.0 (median 13.8) years after tetralogy of Fallot (TOF) repair, and 2 patients with failed bovine jugular vein conduit (BJVC). Seven patients underwent Ross operations. Among them, 3 were for aortic valve stenosis, 2 were for aortic regurgitation, and 2 were for both stenosis and regurgitation. The ePTFE valved conduits were standard hand-sewn during the surgery. The 3 leaflets were equal in size with arc-shaped lower edge of the valve sinus. The free edge of the valve leaflets was straight with the length of about 1 mm longer than the diameter. The height of the valve sinus was 4/5 of the diameter. The junction of the valve leaflet was 3/4 of the height of the sinus. The designed leaflets were then continuous non-penetrating sutured into the inner surface of Gore-Tex vessel to make a valved conduit. Valved conduits with diameter of 18, 20, and 22 mm were used in 2, 9, and 10 cases, respectively. The surgical results, postoperative recovery time, and serious complications were summarized, and the changes of postoperative cardiac function status and hemodynamic status of the conduits were investigated.@*RESULTS@#During the implantation of ePTFE valved conduit for RVOT reconstruction, 2 patients underwent mechanical mitral valve replacement with Ross operation, 2 patients with pulmonary regurgitation with repaired TOF underwent left and right pulmonary artery angioplasty, and 1 patient with failed BJVC underwent tricuspid valvuloplasty. The cardiopulmonary bypassing time for patients underwent re-reconstruction of RVOT was (130.9±16.9) min, with aorta clamping for 1 patient to repair the residual defect of the ventricular septum. The cardiopulmonary bypassing and aorta clamping time for Ross operation were (242.7±20.6) min and (145.6±10.5) min, respectively. The duration of postoperative ventilator assistance, intensive care unit stay, and hospital stay were 3.5 h to 7.7 d (median 17.1 h),11.2 h to 29.5 d (median 1.9 d), and 6.0 to 56.0 (median 13.0) d, respectively. All patients survived after discharge from hospital. The follow-up rate after discharge was 100% with median time at 15.0 (13.0 to 39.0) months. No death happened during the follow-up. One patient underwent stent implantation due to right coronary stenosis 2 months after Ross operation. One patient underwent balloon dilation due to right pulmonary artery ostium stenosis 1 year after re-reconstruction of RVOT. The cardiac function of all patients recovered to NYHA class I 6 months after operation. The peak pressure gradient across the valve measured by transthoracic echocardiography before discharge was (9.4±2.6) mmHg (1 mmHg=0.133 kPa), and (18.3±6.1) mmHg at the last follow-up. There was no significant increase in the gradient during the follow-up (P=0.134). No patient suffered from mild or more pulmonary regurgitation.@*CONCLUSIONS@#Hand-sewn ePTFE valved conduit is feasible for RVOT reconstruction. It is a promising material for RVOT reconstruction which can effectively meet clinical need. In our experience, the ePTFE valved conduit is simple to manufacture with satisfactory early outcomes.In the application of ePTFE valved conduit, attention should be paid to implantation indications and postoperative anticoagulation management, especially to the preparation details of the valved conduit, to obtain better function and durability of the conduit after implantation.


Subject(s)
Adolescent , Animals , Cattle , Humans , Infant , Constriction, Pathologic/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Polytetrafluoroethylene , Prosthesis Design , Pulmonary Valve Insufficiency/surgery , Retrospective Studies , Treatment Outcome , Ventricular Outflow Obstruction/surgery
3.
Rev. argent. neurocir ; 35(2): 107-115, jun. 2021. ilus
Article in Spanish | LILACS, BINACIS | ID: biblio-1398028

ABSTRACT

Intoducción: El tratamiento microquirúrgico para los aneurismas intracraneales es el clipado, sin embargo, algunos aneurismas deben ser resueltos mediante wrapping. El objetivo del trabajo es analizar los cambios histológicos en aneurismas fusiformes en ratas luego del wrapping con algodón natural y politetrafluoroetileno. Materiales y Método: Se trabajó con 12 Ratas Wistar divididas en 3 grupos. Luego de la anestesia se expusieron ambas arterias carótidas comunes, realizándose un aneurisma fusiforme en cada vaso. Se realizó wrapping a las carótidas derechas, grupo 1 con membrana de politetrafluoroetileno, grupo 2 con algodón natural y grupo 3 empleándo combinación de ambos materiales. Los animales fueron sacrificados a los 45 días postoperatorios, para luego procesar las muestras y análisis histológico vascular. Resultados: En el grupo 1 no se evidenciaron modificaciones estructurales, en el grupo 2 se destacó la presencia de células gigantes multinucleadas, inflamación, con infiltrado linfoplasmocitario. En el grupo 3 fue similar al grupo 2 con el agregado de metaplasia condroide y calcificaciones en capa media. Las arterias carotidas izquierdas (control) no presentaron cambios histológicos y a nivel muscular, aumento del tejido conectivo entre las fibras musculares y fibroblastos en el grupo 2. Discusión: Existen publicaciones sobre la técnica de wrapping con materiales autólogos o heterólogos. Sin embargo, no existen análisis experimentales de los efectos microestructurales producidos en las arterias tras la creación y tratamiento de un aneurisma fusiforme. Conclusiones: La combinación más efectiva para reforzar la pared del aneurisma y evitar la reacción inflamatoria circundante es la utilización de algodón natural y politetrafluoroetileno


Intoduction: The microsurgical treatment for intracranial aneurysms is clipping, however, some aneurysms must be resolved by wrapping. The objective of the work is to analyze the histological changes in fusiforms aneurysms in rats after wrapping with natural cotton and polytetrafluoroethylene. Materials and Method: We worked with 12 Wistar rats divided into 3 groups. After anesthesia, both common carotid arteries were exposed, making a fusiform aneurysm in each vessel. Right carotid wrapping was performed, group 1 with a polytetrafluoroethylene membrane, group 2 with natural cotton, and group 3 using a combination of both materials. The animals were sacrificed 45 days after surgery, to process the specimens and vascular histological analysis. Results: In group 1 there were no structural modifications, in group 2 the presence of multinucleated giant cells, inflammation, with lymphoplasmacytic infiltrate stood out. In group 3 it was similar to group 2 with the addition of chondroid metaplasia and calcifications in the middle layer. The left carotid arteries (control) did not present histological changes and at the muscle level, increased connective tissue between muscle fibers and fibroblasts in group 2. Discussion: There are publications on the wrapping technique with autologous or heterologous materials. However, there are no experimental analyzes of the microstructural effects produced in the arteries after the creation and treatment of a fusiform aneurysm. Conclusions: The most effective combination to reinforce the wall of the aneurysm and avoid the surrounding inflammatory reaction is the use of natural cotton and polytetrafluoroethylene


Subject(s)
Aneurysm , Polytetrafluoroethylene , Intracranial Aneurysm
4.
Rev. bras. cir. cardiovasc ; 36(1): 39-47, Jan.-Feb. 2021. tab, graf
Article in English | LILACS | ID: biblio-1155795

ABSTRACT

Abstract Introduction: Reconstruction of right ventricular outflow tract during primary repair of tetralogy of Fallot often requires the placement of a transannular patch which results in pulmonary regurgitation (PR). We compared the short-term outcomes of bicuspid polytetrafluoroethylene membrane valve versus transannular pericardial patch reconstruction of the right ventricular outflow tract. Methods: Thirty consecutive patients undergoing primary repair of tetralogy of Fallot were randomly allocated to two groups - polytetrafluoroethylene valve (PTFEV) group (n=15) and transannular pericardial patch (TAP) group (n=15). The two groups had similar preoperative demographic characteristics. We compared the short-term clinical and echocardiographic outcomes between these groups. The transthoracic echocardiographic follow-up was performed at one week, one month and six months after surgery. Results: The PTFEV group had significantly lower central venous pressure in the immediate postoperative period compared to the TAP group (7.60±2.06 vs. 10.13±1.73, P=0.002). Extubation time was significantly shorter in the PTFEV group compared to the TAP group (12.93±7.55 hrs vs. 22.23±15.11 hrs, P=0.04). PR in the PTFEV group was absent in five patients at 24 hours post-surgery. At the study endpoint, PR was absent in six, trivial in one and mild in eight patients in the PTFEV group compared to TAP group, where all 15 patients had severe PR. Conclusion: The bicuspid polytetrafluoroethylene membrane valves significantly decrease the central venous pressure in the immediate postoperative period, facilitate early extubation and, thus, prevent ventilator-related comorbidities. They achieve a high degree of pulmonary competence and do not increase the right ventricular outflow tract gradient in short-term follow-up.


Subject(s)
Humans , Infant , Pulmonary Valve/surgery , Pulmonary Valve Insufficiency , Tetralogy of Fallot/surgery , Cardiac Surgical Procedures , Polytetrafluoroethylene , Treatment Outcome
5.
Rev. Col. Bras. Cir ; 48: e20202587, 2021. graf
Article in English | LILACS | ID: biblio-1155357

ABSTRACT

ABSTRACT Objectives: the aim of this study was to compare the outcomes of a new silicone vascular prostheses with PTFE vascular prostheses, on a rabbit experimental model. Methods: forty rabbits underwent infra-renal aorta replacement with 4 mm diameter prostheses, twenty animals with PDMS and twenty animals with PTFE (control group). Retrograde aortic angiography was performed to assess patency. Histological graft samples were examined by electron microscopy to evaluate prostheses endothelialization. Results: patency rates were 100% for both grafts after 30 days; after 60 days, patency rate for PDMS was 92.3% (±7.4), and 73,8% (±13.1) at 90 days. PTFE grafts had patency rates of 87.5% (±11.7) at 60 and 90 days. No statistically significant difference was found in between groups for patency rates (p=0.62). Postoperative complications (death, paraplegia) rates (p=0.526) and aortic clamping times (p=0.299) were comparable in both groups. No statistically significant difference for stenosis was found on angiographical analysis between groups (p=0.650). Electron microscopy revealed limited anastomotic endothelial ingrowth in both prostheses. Conclusion: in this experimental model, PDMS and PTFE vascular prostheses had comparable outcomes and PDMS prosthesis could be used as a vascular graft.


RESUMO Objetivo: analisar novo tubo de silicone como material para prótese vascular e compará-lo a prótese de PTFE, em modelo experimental com coelhos. Métodos: quarenta coelhos foram submetidos a interposição, na aorta infrarrenal, de próteses de 4mm de diâmetro, sendo 20 animais com PDMS e 20 com PTFE (grupo controle). Foi realizada arteriografia retrógrada da aorta para avaliar a patência das próteses. Para avaliar a endotelização das próteses foi realizada microscopia eletrônica de maneira amostral pareada. Resultados: a patência em 30 dias foi de 100% para as duas próteses. Aos 60 dias, a taxa de patência do PDMS foi de 92,3% (± 7,4), e de 73,8% (±13,1) em 90 dias; as próteses de PTFE tiveram taxas de patência de 87,5% (± 11,7) aos 60 e 90 dias. Não foi observada diferença significativa entre as taxas de patência dos grupos (p=0,62). Não foi observada diferença entre os grupos quanto à evolução com complicações pós-operatórias (p=0,526) e quanto ao tempo de clampeamento da aorta (p=0,299). Não houve diferença significativa entre os grupos quanto ao grau de estenose das próteses (p=0,650) à avaliação angiográfica. A microscopia eletrônica mostrou crescimento endotelial limitado às regiões próximas às anastomoses nos dois tipos de próteses. Conclusões: o PDMS mostrou-se passível de utilização como prótese vascular, com resultados comparáveis aos do PTFE no modelo utilizado.


Subject(s)
Animals , Aorta/surgery , Polytetrafluoroethylene/therapeutic use , Silicones/therapeutic use , Blood Vessel Prosthesis , Polyesters , Rabbits
6.
J. vasc. bras ; 20: e20200157, 2021. tab
Article in English | LILACS | ID: biblio-1279377

ABSTRACT

Abstract Background Diagnosis of the etiologic agent of endoprosthesis infections is essential to enable treatment, since these infections constitute important complications of endovascular procedures. Sonication of explanted tissue and materials is a technique that can be used to facilitate detection of biofilm-producing bacteria. Objectives To evaluate infection of pigs' aortas after implantation of nitinol stents coated with polytetrafluoroethylene (ePTFE) or Dacron, previously infected with biofilm-producing Staphylococcus epidermidis. Intimal thickening and the inflammatory response in the aortic wall were also evaluated. Methods 11 ePTFE-coated nitinol stents and 10 Dacron stents infected with S. epidermidis strains were implanted in the infrarenal aorta of 21 8-week-old pigs. After 2 weeks, the aorta containing the stents was removed. A vortex mixer and ultrasound were used to homogenize the samples and remove the biofilm. Subsequently, the number of colony-forming units was counted. Results There were no significant differences between the two groups in terms of the number of colony-forming units or of inflammation in the arterial wall. With the exception of one specimen from the Dacron group, all aortic stent cultures were positive for S. epidermidis. Conclusions There were no significant differences in the inflammatory response or infection rate between ePTFE and Dacron-coated stents actively infected with biofilm-producing S. epidermidis. Intimal thickening and the inflammatory response to infection of endoprostheses were similar. These results suggest that the two most widely used stent lining materials have a similar infection rate.


Resumo Contexto O diagnóstico do agente etiológico é essencial para o tratamento das infecções de endoprótese, pois representam uma importante complicação do tratamento endovascular. A sonificação dos tecidos pode ser uma técnica usada para auxiliar na detecção de bactérias produtoras de biofilme. Objetivos Avaliar a infecção da aorta dos porcos após o implante de stents de nitinol revestidos com politetrafluoretileno (ePTFE) ou Dacron, infectados com Staphylococcus epidermidis, produtor de biofilme. O espessamento intimal e a resposta inflamatória na parede aórtica também foram avaliados. Métodos Onze stents de nitinol revestidos com ePTFE e 10 stents de Dacron infectados com cepas de S. epidermidis foram implantados na aorta infrarrenal de 21 porcos com 8 semanas de idade. Após duas semanas, a aorta contendo os stents foi removida. Um misturador de vórtice e ultrassom foram utilizados para homogeneizar as amostras e remover o biofilme. Posteriormente, o número de unidades formadoras de colônias foi contado. Resultados Não houve diferenças significativas no número de unidades formadoras de colônias ou inflamação na parede arterial entre os dois grupos. Todas as culturas de stent aórtico foram positivas para S. epidermidis, exceto uma no grupo Dacron. Conclusões Não houve diferenças significativas na resposta inflamatória ou na taxa de infecção entre os stents revestidos de ePTFE e Dacron, infectados ativamente pelo S. epidermidis produtor de biofilme. O espessamento intimal e a resposta inflamatória à infecção das endopróteses foram semelhantes. Esses resultados sugerem que os dois materiais de revestimento de stent mais amplamente utilizados têm uma taxa de infecção semelhante.


Subject(s)
Animals , Sonication , Staphylococcus epidermidis , Stents , Aorta , Polytetrafluoroethylene , Staphylococcal Infections , Swine , Endovascular Procedures
7.
Acta méd. costarric ; 62(3)sept. 2020.
Article in Spanish | LILACS, SaludCR | ID: biblio-1383328

ABSTRACT

Resumen Objetivo: Investigar con cuál técnica quirúrgica, cierre directo o con parche de Goretex, las hernias diafragmáticas congénitas operadas tienen más recidiva. Metodología: Los datos de los pacientes sometidos a reparación por hernia diafragmática congénita en el Hospital Nacional de Niños, entre enero 2008 y el 31 diciembre de 2017, fueron revisados retrospectivamente. De los 94 pacientes, solo 59 cumplen con los criterios de inclusión. Para la comparación de las variables cuantitativas se empleó pruebas de T de Student e intervalos de confianza al 95 %; las variables cualitativas se analizaron por la prueba de Fisher con un nivel de significancia de 0,05. Resultados: La mayoría de las hernias diafragmáticas operadas fueron izquierdas (78 %) y posterolaterales (91 %). La técnica de reparación más frecuente utilizada fue el cierre directo (68%). Hubo más recidivas posteriores a cierre con parche de Goretex. Se presentaron entre 1 y 12 meses postoperatorio. No hubo diferencia estadísticamente significativa entre recidivas con técnica de cierre directo versus cierre con parche de Goretex. Conclusión: Realizar un cierre directo del diafragma es una buena opción quirúrgica para reparación de hernia diafragmática congénita. No hubo en este estudio diferencias estadísticamente significativas en cuanto a recidiva entre utilizar técnica con cierre directo o con parche.


Abstract Objective: To investigate with which surgical technique, direct closure or use of a Goretex patch, congenital diaphragmatic hernias recurre more. Methodology: The data of the patients who underwent repair of congenital diaphragmatic hernia at the National Children's Hospital from January 2008 to December 31, 2017, were reviewed retrospectively. Of the 94 patients, only 59 met the inclusion criteria. For the comparison of the quantitative variables, Student's t-test and 95% confidence intervals were used, the qualitative variables were analyzed by the Fisher's test with a significance level of 0.05. Results: Most of the operated diaphragmatic hernias were left 78% and posterolateral 91%. The most frequent repair technique used was direct closure, 68%. There were more recurrences after closing when a Goretex patch was used. They occurred between 1 and 12 months post-operatively. There was no statistically significant difference between recurrences with the direct closure technique versus closure with the Goretexpatch. Conclusion: Performing a direct closure of the diaphragm is a good surgical option for surgical repair of congenital diaphragmatic hernias. There were no statistically significant differences in relapse in this study between using the direct closure or patch technique.


Subject(s)
Humans , Child, Preschool , Child , Polytetrafluoroethylene/therapeutic use , Hernia, Diaphragmatic/surgery , Costa Rica
8.
Arq. bras. oftalmol ; 83(1): 39-42, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088957

ABSTRACT

ABSTRACT Purpose: To review the outcomes of frontalis suspension surgeries with the use of polytetrafluoroethylene in patients with blepharoptosis. Methods: A retrospective observational study analyzed the outcomes of frontalis suspension surgeries performed in a single institution from 2003 to 2018. All procedures were performed with closed incision and single pentagon techniques. Outcomes were classified as satisfactory or unsatisfactory, with satisfactory defined as a margin reflex distance of >3 mm and <1 mm between eyelids and unsatisfactory as hypocorrection, surgical complications, and asymmetry. Results: We included a total of 76 eyelids from 52 patients in our study. Within a mean postoperative follow-up of 16.8 ± 18.5 months (range, 3-95), 59 (77.6%) eyelids had a satisfactory outcome, and 17 (22.4%) were unsatisfactory (8 cases of asymmetry, 3 granulomas, 3 suture extrusions, 2 abscesses, and 1 case of cellulitis). Nine eyelids from the unsatisfactory group required reoperation. Among the patients with a follow-up of ³12 months (38 surgeries), lasting results were observed in most eyelids, except for 2 late-onset suture extrusions. Conclusion: The use of polytetrafluoroethylene in frontalis suspension surgery was shown to be predictable, safe, and lasting. Our findings support previous studies that have shown adequate functional results and low complication rates.


RESUMO Objetivo: Revisar os resultados de cirurgias de sus pensão ao músculo frontal com o uso de fio de politetrafluoretileno em pacientes com blefaroptose. Métodos: Em um estudo observacional retrospectivo, foram analisados os resultados das cirurgias de músculo frontal de uma instituição, realizadas entre 2003 e 2018. Todos os procedimentos foram realizados com incisão fechada e técnica de pentágono. Os desfechos foram classificados como satisfatórios ou insatisfatórios com definição satisfatória definida como distância margem-reflexo >3mm e <1mm entre as pálpebras e insatisfatória como hipocorreção, complicações cirúrgicas e assimetria. Resultados: Incluímos um total de 76 pálpebras de 52 pacientes em nosso estudo. Com um tempo médio de seguimento pós-operatório de 16,8 ± 18,5 meses (intervalo 3-95), 59 (77,6%) pálpebras apresentaram desfecho satisfatório e 17 (22,4%) insatisfatórios (8 casos de assimetria, 3 granulomas, 3 extrusões de sutura, 2 abscessos e 1 caso de celulite). Nove pálpebras do grupo insatisfatório necessitaram de reoperação. Entre os pacientes com seguimento ³12 meses (38 cirurgias), resultados duradouros foram observados na maioria dos casos, exceto por 2 extrusões de sutura de surgimento tardio. Conclusão: O uso de politetrafluoretileno na cirurgia de músculo frontal mostrou ser previsível, seguro e duradouro, Nossos achados corroboram com estudos prévios que mostraram resultados funcionais adequados e baixos índices de complicação.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Young Adult , Polytetrafluoroethylene/therapeutic use , Blepharoptosis/surgery , Blepharoplasty/methods , Eyelids/surgery , Oculomotor Muscles/surgery , Postoperative Complications , Reoperation , Retrospective Studies , Suture Techniques , Treatment Outcome
9.
Acta cir. bras ; 34(7): e201900703, 2019. tab, graf
Article in English | LILACS | ID: biblio-1038114

ABSTRACT

Abstract Purpose: To compare four types of mesh regarding visceral adhesions, inflammatory response and incorporation. Methods: Sixty Wistar rats were divided into four groups, with different meshes implanted intraperitoneally: polytetrafluoroethylene (ePTFE group); polypropylene with polydioxanone and oxidized cellulose (PCD); polypropylene (PM) and polypropylene with silicone (PMS). The variables analyzed were: area covered by adhesions, incorporation of the mesh and inflammatory reaction (evaluated histologically and by COX2 immunochemistry). Results: The PMS group had the lowest adhesion area (63.1%) and grade 1 adhesions. The ePTFE and PM groups presented almost the total area of their surface covered by adherences (99.8% and 97.7% respectively) The group ePTFE had the highest percentage of area without incorporation (42%; p <0.001) with no difference between the other meshes. The PMS group had the best incorporation rate. And the histological analysis revealed that the inflammation scores were significantly different. Conclusions: The PM mesh had higher density of adherences, larger area of adherences, adherences to organs and percentage of incorporation. ePTFE had the higher area of adherences and lower incorporation. The PMS mesh performed best in the inflammation score, had a higher incorporation and lower area of adherences, and it was considered the best type of mesh.


Subject(s)
Animals , Male , Rats , Prostheses and Implants/adverse effects , Surgical Mesh/standards , Tissue Adhesions/pathology , Incisional Hernia/surgery , Inflammation/pathology , Polypropylenes/adverse effects , Polytetrafluoroethylene/adverse effects , Postoperative Complications/prevention & control , Silicones/adverse effects , Surgical Mesh/adverse effects , Materials Testing , Viscera/physiology , Cellulose, Oxidized/adverse effects , Tissue Adhesions/prevention & control , Rats, Wistar , Statistics, Nonparametric , Abdominal Wall
10.
Journal of Korean Neurosurgical Society ; : 635-642, 2019.
Article in English | WPRIM | ID: wpr-788823

ABSTRACT

OBJECTIVE: The aim of this study was to investigate the biomechanical differences between human dura mater and dura mater substitutes to optimize biomimetic materials.METHODS: Four groups were investigated. Group I used cranial dura mater (n=10), group II used Gore-Tex® Expanded Cardiovascular Patch (W.L. Gore & Associates Inc., Flagstaff, AZ, USA) (n=6), group III used Durepair® (Medtronic Inc., Goleta, CA, USA) (n=6), and group IV used Tutopatch® (Tutogen Medical GmbH, Neunkirchen am Brand, Germany) (n=6). We used an axial compression machine to measure maximum tensile strength.RESULTS: The mean tensile strengths were 7.01±0.77 MPa for group I, 22.03±0.60 MPa for group II, 19.59±0.65 MPa for group III, and 3.51±0.63 MPa for group IV. The materials in groups II and III were stronger than those in group I. However, the materials in group IV were weaker than those in group I.CONCLUSION: An important dura mater graft property is biomechanical similarity to cranial human dura mater. This biomechanical study contributed to the future development of artificial dura mater substitutes with biomechanical properties similar to those of human dura mater.


Subject(s)
Humans , Biomimetic Materials , Collagen , Dura Mater , In Vitro Techniques , Mechanics , Pericardium , Polytetrafluoroethylene , Tensile Strength , Transplants
11.
Restorative Dentistry & Endodontics ; : e1-2019.
Article in English | WPRIM | ID: wpr-741990

ABSTRACT

OBJECTIVES: The aim of this in vitro study was to test the effect of 2 finishing–polishing sequences (QB, combining a 12/15-fluted finishing bur and an EVO-Light polisher; QWB, adding a 30-fluted polishing bur after the 12/15-fluted finishing bur used in the QB sequence) on 5 nanotech-based resin composites (Filtek Z500, Ceram X Mono, Ceram X Duo, Tetric Evoceram, and Tetric Evoceram Bulk Fill) by comparing their final surface roughness and hardness values to those of a Mylar strip control group (MS). MATERIALS AND METHODS: Twelve specimens of each nanocomposite were prepared in Teflon moulds. The surface of each resin composite was finished with QB (5 samples), QWB (5 samples), or MS (2 samples), and then evaluated (60 samples). Roughness was analysed with an optical profilometer, microhardness was tested with a Vickers indenter, and the surfaces were examined by optical and scanning electron microscopy. Data were analysed using the Kruskal-Wallis test (p < 0.05) followed by the Dunn test. RESULTS: For the hardness and roughness of nanocomposite resin, the QWB sequence was significantly more effective than QB (p < 0.05). The Filtek Z500 showed significantly harder surfaces regardless of the finishing–polishing sequence (p < 0.05). CONCLUSIONS: QWB yielded the best values of surface roughness and hardness. The hardness and roughness of the 5 nanocomposites presented less significant differences when QWB was used.


Subject(s)
Composite Resins , Dental Polishing , Hardness , In Vitro Techniques , Microscopy, Electron, Scanning , Nanocomposites , Polytetrafluoroethylene
12.
Clinical Psychopharmacology and Neuroscience ; : 244-249, 2019.
Article in English | WPRIM | ID: wpr-763533

ABSTRACT

OBJECTIVE: Findings about inflammatory processes in schizophrenia are increasing day by day. Inflammatory processes in schizophrenia are associated with both its etiology and clinical symptoms. Serum high-sensitivity C-reactive protein (hsCRP) is also one of these inflammatory processes. Particularly, it is thought to be closely related to clinical findings of patients with schizophrenia. METHODS: In this study, the relationship between clinical findings of hsCRP levels of patients with drug-naïve first-episode psychosis (FEP) and patients with schizophrenia in acute exacerbation phase is investigated. Clinical findings, psychometric properties (the Scale for the Assessment of Positive Symptoms, the Scale for the Assessment of Negative Symptoms, Brief Psychiatric Rating Scale), and hsCRP levels of patients were compared. RESULTS: Forty-eight patients with FEP, 74 patients with schizophrenia in acute exacerbation phase and 54 healthy controlled volunteers are included in the study. The most substantial finding in the study is that there is a positive correlation between hsCRP levels and severity of positive symptoms of both patient groups, with FEP and with schizophrenia. The second most substantial finding is there is no significant difference between patients with FEP and schizophrenia, in terms of hsCRP. CONCLUSION: The relationship between hsCRP and positive symptom severity in two groups of patients supports the inflammatory hypothesis in the etiopathogenesis of schizophrenia. This finding is supportive of close relation between inflammatory processes and clinical findings of patient with schizophrenia.


Subject(s)
Humans , C-Reactive Protein , Polytetrafluoroethylene , Psychometrics , Psychotic Disorders , Schizophrenia , Volunteers
13.
Korean Journal of Ophthalmology ; : 8-15, 2019.
Article in English | WPRIM | ID: wpr-741304

ABSTRACT

PURPOSE: To investigate the clinical manifestations and properties of remnant particles in the subconjunctival space after high-frequency radio-wave electrosurgery for conjunctivochalasis. METHODS: We performed a retrospective, observational case series with in vitro experimental imaging in nine eyes from eight patients who presented with small dark-gray lesions during follow-up after high-frequency radio-wave electrosurgery for conjunctivochalasis. General examination including slit-lamp examination and visual acuity testing was performed preoperatively and postoperatively. During follow-up, we evaluated remnant particles and any other complications including granuloma or conjunctival injection with slit-lamp photography and anterior optical coherence tomography. Coagulation tips were investigated with scanning electron microscope and energy dispersive X-ray spectroscopy to analyze the insulating electrode and assess changes to tips after repeated use. RESULTS: None of the patients included in this study experienced any change in visual acuity or major complications postoperatively. Small dark-gray lesions (0.3 to 0.5 mm in size) were observed in the inferior bulbar sub-conjunctival space in the location where high-frequency radio-wave electrosurgery had been performed. Cirrus high-definition optical coherence tomography images revealed focal hyper-reflection with a posterior shadow, suggesting foreign particles. Scanning electron microscopy and energy dispersive X-ray spectroscopy imaging analysis revealed peaks of carbon and fluorine complexes, consistent with the polytetrafluoroethylene coating on the electrode. CONCLUSIONS: There were no instances of inflammatory reaction, particle migration, or major complications due to particles. Physicians should be aware of the possibility of remnant polytetrafluoroethylene particles in subconjunctival tissue when using insulated coagulation tips subjected to repeat sterilization.


Subject(s)
Humans , Carbon , Electrodes , Electrosurgery , Fluorine , Follow-Up Studies , Granuloma , In Vitro Techniques , Microscopy, Electron, Scanning , Photography , Polytetrafluoroethylene , Retrospective Studies , Spectrometry, X-Ray Emission , Sterilization , Tomography, Optical Coherence , Visual Acuity
14.
Vascular Specialist International ; : 165-169, 2019.
Article in English | WPRIM | ID: wpr-762023

ABSTRACT

A 58-year-old male patient with severe claudication due to thrombosis of the left ilio-femoro-popliteal artery aneurysm. He also had a venous stasis ulcer with a history of multiple embolotherapy of arteriovenous malformation. Duplex sonography revealed reflux and varicose veins of the left great saphenous vein (GSV). A sequential bypass surgery was performed that consisted of excision of the left external iliac and common femoral artery aneurysm, external iliac to deep femoral interposition with an expanded polytetrafluoroethylene graft, and femoro-posterior tibial artery bypass with the reversed left GSV. Symptoms of claudication were alleviated and the chronic ulcer was healed in time. To our knowledge, this is the first report of successful bypass in a patient with arterial aneurysm, arteriovenous malformation, and venous insufficiency that can be diagnosed as an atypical case of Parkes Weber syndrome. Long-term follow-up is needed to define the fate of aneurysms and varicose vein graft.


Subject(s)
Humans , Male , Middle Aged , Aneurysm , Arteries , Arteriovenous Fistula , Arteriovenous Malformations , Embolization, Therapeutic , Femoral Artery , Follow-Up Studies , Polytetrafluoroethylene , Popliteal Artery , Saphenous Vein , Sturge-Weber Syndrome , Thrombosis , Tibial Arteries , Transplants , Ulcer , Varicose Ulcer , Varicose Veins , Venous Insufficiency
15.
Vascular Specialist International ; : 111-113, 2019.
Article in English | WPRIM | ID: wpr-762011

ABSTRACT

An iatrogenic internal carotid artery (ICA) pseudoaneurysm is an extremely rare complication of cervical spine surgery. Here we report an extraordinary case of massive hematemesis due to a ruptured ICA pseudoaneurysm caused by the laminoplasty plate 10 years after cervical spine surgery. Computed tomography angiography revealed a ruptured 4×10-mm left extracranial ICA pseudoaneurysm probably connected to the pharynx. Emergent surgery was performed because of the uncontrolled massive bleeding. After complete resection of the injured segment, an interposition graft with a 6-mm polytetrafluoroethylene graft was placed and the fistula tract to the pharynx was repaired.


Subject(s)
Aneurysm, False , Angiography , Carotid Artery, Internal , Fistula , Hematemesis , Hemorrhage , Laminoplasty , Pharynx , Polytetrafluoroethylene , Spine , Transplants
16.
Vascular Specialist International ; : 34-38, 2019.
Article in English | WPRIM | ID: wpr-762003

ABSTRACT

Iliac artery aneurysms are usually asymptomatic. Herein, we report a novel strategy for the repair of a pseudoaneurysm involving the external iliac artery using a conventional artificial graft and bare metal stent. A 76-year-old male patient presented with severe resting pain and right foot discoloration. Computed tomography angiography revealed a right distal external iliac artery pseudoaneurysm, with severe calcified occlusion at the right common and superficial femoral arteries. After exposing the right femoral artery, long-segment endarterectomy and patch angioplasty with the ipsilateral greater saphenous vein were performed. Before the completion of patch angioplasty, a surgeon-modified 8-mm expanded polytetrafluoroethylene (ePTFE) graft was inserted for complete pseudoaneurysm repair. If a commercial covered stent is not available, minimally invasive endovascular repair can be safely performed using a surgeon-modified ePTFE graft and bare metal stent.


Subject(s)
Aged , Humans , Male , Aneurysm , Aneurysm, False , Angiography , Angioplasty , Endarterectomy , Femoral Artery , Foot , Iliac Artery , Polytetrafluoroethylene , Prostheses and Implants , Saphenous Vein , Stents , Transplants
17.
Psychiatry Investigation ; : 695-703, 2019.
Article in English | WPRIM | ID: wpr-760978

ABSTRACT

OBJECTIVE: Although early intervention from the beginning of a psychotic episode is essential for a better prognosis, biomarkers predictive of symptomatic and functional improvement in early psychotic disorders are lacking. This study aimed to investigate whether the spectral power of resting-state electroencephalography (EEG) can be used as a predictive marker of the 1-year prognosis in patients with first-episode psychosis (FEP). METHODS: Twenty-four patients with FEP and matched healthy control (HC) subjects were examined with resting-state EEG at baseline. The symptomatic severity and functional status of FEP patients were assessed at baseline and reassessed after 1 year of usual treatment. Repeated measures analysis of variance was conducted to compare EEG spectral powers across the groups. Multiple regression analysis revealed EEG spectral powers predictive of symptomatic and functional improvement in FEP patients at the 1-year follow-up. RESULTS: Delta band power in the frontal and posterior regions was significantly higher in patients with FEP than in HCs. Higher delta band power in the posterior region predicted later improvement of positive symptoms and general functional status. Lower delta band power in the frontal region predicted improvement of negative symptoms and general functioning after 1 year. CONCLUSION: These results suggest that increased delta absolute power is observed from the beginning of psychotic disorders. Furthermore, decreased delta power in the frontal region and increased delta power in the posterior region might be used as a predictive marker of a better prognosis of FEP, which would aid early intervention in clinical practice.


Subject(s)
Humans , Biomarkers , Early Intervention, Educational , Electroencephalography , Follow-Up Studies , Polytetrafluoroethylene , Prognosis , Psychotic Disorders
18.
Psychiatry Investigation ; : 177-184, 2019.
Article in English | WPRIM | ID: wpr-760920

ABSTRACT

OBJECTIVE: Schizophrenia is a disabling disorder of unknown aetiology, lacking definite diagnostic method and cure. A reliable biological marker of schizophrenia is highly demanded, for which traceable immune mediators in blood could be promising candidates. We aimed to gather the best findings of neuroinflammatory markers for first-episode psychosis (FEP). METHODS: We performed an extensive narrative review of online literature on inflammation-related markers found in human FEP patients only. RESULTS: Changes to cytokine levels have been increasingly reported in schizophrenia. The peripheral levels of IL-1 (or its receptor antagonist), soluble IL-2 receptor, IL-4, IL-6, IL-8, and TNF-α have been frequently reported as increased in FEP, in a suggestive continuum from high-risk stages for psychosis. Microglia and astrocytes establish the link between this immune signalling and the synthesis of noxious tryptophan catabolism products, that cause structural damage and directly hamper normal neurotransmission. Amongst these, only 3-hydroxykynurenine has been consistently described in the blood of FEP patients. CONCLUSION: Peripheral molecules stemming from brain inflammation might provide insightful biomarkers of schizophrenia, as early as FEP or even prodromal phases, although more time- and clinically-adjusted studies are essential for their validation.


Subject(s)
Humans , Astrocytes , Biomarkers , Encephalitis , Interleukin-1 , Interleukin-4 , Interleukin-6 , Interleukin-8 , Metabolism , Methods , Microglia , Polytetrafluoroethylene , Psychotic Disorders , Receptors, Interleukin-2 , Schizophrenia , Synaptic Transmission , Tryptophan
19.
Journal of Korean Neurosurgical Society ; : 635-642, 2019.
Article in English | WPRIM | ID: wpr-765397

ABSTRACT

OBJECTIVE: The aim of this study was to investigate the biomechanical differences between human dura mater and dura mater substitutes to optimize biomimetic materials. METHODS: Four groups were investigated. Group I used cranial dura mater (n=10), group II used Gore-Tex® Expanded Cardiovascular Patch (W.L. Gore & Associates Inc., Flagstaff, AZ, USA) (n=6), group III used Durepair® (Medtronic Inc., Goleta, CA, USA) (n=6), and group IV used Tutopatch® (Tutogen Medical GmbH, Neunkirchen am Brand, Germany) (n=6). We used an axial compression machine to measure maximum tensile strength. RESULTS: The mean tensile strengths were 7.01±0.77 MPa for group I, 22.03±0.60 MPa for group II, 19.59±0.65 MPa for group III, and 3.51±0.63 MPa for group IV. The materials in groups II and III were stronger than those in group I. However, the materials in group IV were weaker than those in group I. CONCLUSION: An important dura mater graft property is biomechanical similarity to cranial human dura mater. This biomechanical study contributed to the future development of artificial dura mater substitutes with biomechanical properties similar to those of human dura mater.


Subject(s)
Humans , Biomimetic Materials , Collagen , Dura Mater , In Vitro Techniques , Mechanics , Pericardium , Polytetrafluoroethylene , Tensile Strength , Transplants
20.
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 363-366, 2018.
Article in English | WPRIM | ID: wpr-717302

ABSTRACT

One of the complications of permanent pacemaker implantation is unintended phrenic nerve stimulation. A 15-year-old boy with a permanent pacemaker presented with chest discomfort due to synchronous chest wall contraction with pacing beats. Even after reprogramming of the pacemaker, diaphragmatic stimulation persisted. Therefore, we performed thoracoscopic phrenic nerve insulation using a Gore-Tex patch to insulate the phrenic nerve from the wire. A minimally invasive approach using a thoracoscope is a feasible option for retractable phrenic nerve stimulation after pacemaker implantation.


Subject(s)
Adolescent , Humans , Male , Minimally Invasive Surgical Procedures , Pacemaker, Artificial , Phrenic Nerve , Polytetrafluoroethylene , Thoracic Wall , Thoracoscopes , Thoracoscopy , Thorax
SELECTION OF CITATIONS
SEARCH DETAIL